| 7SD5225-2AB99-9CJ0 L0S+M0G+N0G |
7SD |
TWO TERMINAL DIFFERENT. RELAY WITH 4-LINE DISPLAY MEASUREMENT INPUT: IPH = 5A; IE = 5A AUXIL. VOLTAGE: 24V TO 48V DC BINARY INPUT THRESHOLD 19V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/2 X 19", 8 BI, 15 BO, 1 LIVE-STATUS CONTACT REGION WORLD,LANGUAGE UK-ENGL. (LANGUAGE CHANGEABLE) PORT B: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR (FROM OCT. 09) NO DIGSI INTERFACE ON REAR OF DEVICE, PROTECTION DATA INTERFACE 1: OPTICAL 1300NM,LC-DUPLEX CONNE. FIBER LENGTH UP TO 24 KM FOR DIRECT CONNECTION VIA MONO-MODE FIBER FUNCTION 1: TRIP MODE 3-POLE ONLY, WITHOUT AUTO RECLOSURE FUNCTION WITHOUT SYNCHRONISM CHECK PROTECTION INTERFACE 2: OPTICAL 1300NM, 2 LC-DUPLEX CONNECTOR FIBER LENGTH UP TO 24 KM FOR DIRECT CONNECTION WITH MONO-MODE FIBER WITH OVERCURRENT PROTECTION/ BREAKER FAILURE PROTECTION WITH 4 REMOTE COMMANDS, WITH 24 REMOTE MESSAGES, WITHOUT TRANSFORMER EXTENSIONS FAULT LOCATOR 1-SIDE MAESURING W/O MEASURED VALUES EXTENDED, W/O EXTERNAL GPS-SYNCHRONIZAT. WITHOUT CAPACITIVE CURRENT LOAD COMPENSATION |
In stock
|
| 7SD5225-5CB99-2FK0 L0R+M0A |
7SD |
TWO TERMINAL DIFFERENT. RELAY WITH 4-LINE DISPLAY MEASUREMENT INPUT: IPH = 5A; IE = 5A AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/1 X 19", 16 BI, 23 BO, 1 LIVE-STATUS CONTACT REGION WORLD,LANGUAGE UK-ENGL. (LANGUAGE CHANGEABLE) PORT B: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET ELECTRICAL,DOUBLE, RJ45-PLUG NO DIGSI INTERFACE ON REAR OF DEVICE, PROTECTION INTERFACE 1: OPTICAL 820NM,TWO ST-CONNECTORS FO LENGTH UP TO 1,5KM, FOR MULTIMODE FIBER FOR DIRECT CONNECTION OR COMMUNICATION NETWORKS FUNCTION 1: TRIP MODE 1- AND 3-POLE, WITHOUT AUTO RECLOSURE FUNCTION WITHOUT SYNCHRONISM CHECK WITH TIME OVERCURRENT PROTECT./ BREAKER FAILURE PROTECTION/ EARTH FAULT PROTECTION, DIRECTIONAL GROUND (EARTH)- FAULT PROTECTION WITH 4 REMOTE COMMANDS, WITH 24 REMOTE MESSAGES, WITHOUT TRANSFORMER EXTENSIONS FAULT LOCATOR 1-SIDE MEASURING WITH VOLTAGE-/FREQUENCY PROTEC. W/O MEASURED VALUES EXTENDED, W/O EXTERNAL GPS-SYNCHRONIZAT. WITHOUT CAPACITIVE CURRENT LOAD COMPENSATION |
In stock
|
| 7SD5225-6AB09-9CJ0+M2B+N0B |
7SD |
TWO TERMINAL DIFFERENT. RELAY WITH 4-LINE DISPLAY MEASUREMENT INPUT: IPH = 5A; IE = 5A AUXIL. VOLTAGE: 220V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 176V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/2 X 19", 8 BI, 15 BO, 1 LIVE-STATUS CONTACT REGION WORLD,LANGUAGE UK-ENGL. (LANGUAGE CHANGEABLE) NO SYSTEM INTERFACE INTERFACE ON REAR OF DEVICE DIGSI 4, ELECTRICAL RS485 PROTECTION INTERFACE 1: OPTICAL 820NM,TWO ST-CONNECTORS FO LENGTH UP TO 3,5KM FOR DIRECT CONNECTION VIA MULTIMODE FIBER FUNCTION 1: TRIP MODE 3-POLE ONLY, WITHOUT AUTO RECLOSURE FUNCTION WITHOUT SYNCHRONISM CHECK PROTECTION INTERFACE 2: OPTICAL 820NM,TWO ST-CONNECTORS FO LENGTH UP TO 3,5KM FOR DIRECT CONNECTION VIA MULTIMODE FIBER WITH OVERCURRENT PROTECTION/ BREAKER FAILURE PROTECTION WITH 4 REMOTE COMMANDS, WITH 24 REMOTE MESSAGES, WITHOUT TRANSFORMER EXTENSIONS FAULT LOCATOR 1-SIDE MAESURING W/O MEASURED VALUES EXTENDED, W/O EXTERNAL GPS-SYNCHRONIZAT. WITHOUT CAPACITIVE CURRENT LOAD COMPENSATION; ; |
In stock
|
| 7SD5321-4AB99-0FV7 L0S+M2G |
7SD |
TWO TERMINAL DIFFERENT. RELAY WITH GRAPHICAL DISPLAY MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/2 X 19", 8 BI, 15 BO, 1 LIVE-STATUS CONTACT REGION WORLD,LANGUAGE UK-ENGL. (LANGUAGE CHANGEABLE) PORT B: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR (FROM OCT. 09) INTERFACE ON REAR OF DEVICE DIGSI 4, ELECTRICAL RS485 PROTECTION DATA INTERFACE 1: OPTICAL 1300NM,LC-DUPLEX CONNE. FIBER LENGTH UP TO 24 KM FOR DIRECT CONNECTION VIA MONO-MODE FIBER FUNCTION 1: TRIP MODE 3-POLE ONLY, WITHOUT AUTO RECLOSURE FUNCTION WITHOUT SYNCHRONISM CHECK WITH TIME OVERCURRENT PROTECT./ BREAKER FAILURE PROTECTION/ EARTH FAULT PROTECTION, DIRECTIONAL GROUND (EARTH)- FAULT PROTECTION WITH 4 REMOTE COMMANDS, WITH 24 REMOTE MESSAGES, WITH TRANSFORMER EXPANSIONS FAULT LOCATOR 2-SIDE MEASURING WITH VOLTAGE-/FREQUENCY PROTEC. WITH RESTRICTED EARTH FAULT WITH MEASURED VALUES EXTENDED (MIN/MAX VALUES) WITH EXTERNAL GPS SYNCHRONIZAT. WITH CPACITIVE CURRENT LOAD COMPENSATION |
In stock
|
| 7SJ8011-5EB06-1FA0 |
7SJ |
OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A rated auxiliary voltage: 60 V/ 110 V / 125 V/ 220 V DC, 115 V / 230 V AC flush-mounting housing, screw terminals region world, IEC/ANSI language English (language can be changed) front membrane standard no system interface interface, Port A (device bottom side, front) with Ethernet interface (DIGSI interface, not IEC61850) RJ45 plug measurement: fault recording functionality: overcurrent protection+ overcurrent protection PH(50/51) I>,I>>,I>>>,IP ground-fault protection overcurrent protection ground (50N/51N: IE>, IE>>,IE>>>, IEP ground fault/ground short circuit prot. IEE>.IEE>>,IEEP overload protection (49) trip-circuit supervision (74TC) circuit breaker failure protection (50BF), unbalanced-load protection (46) undercurrent supervision (37) lock out (86) parameter set switchover supervision functions circuit-breaker control flexible protection functions (characteristic key values f(*) without automatic reclosing without fault locator |
In stock
|
| 7SJ8011-5EB10-1FA0 |
7SJ |
OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A rated auxiliary voltage: 60 V/ 110 V / 125 V/ 220 V DC, 115 V / 230 V AC flush-mounting housing, screw terminals region world, IEC/ANSI language English (language can be changed) front membrane standard system interface port B (device bottom side, rear) IEC60870-5-103 or DIGSI4/modem, electrical RS232 without system interf., Port A measurement: fault recording functionality: overcurrent protection+ overcurrent protection PH(50/51) I>,I>>,I>>>,IP ground-fault protection overcurrent protection ground (50N/51N: IE>, IE>>,IE>>>, IEP ground fault/ground short circuit prot. IEE>.IEE>>,IEEP overload protection (49) trip-circuit supervision (74TC) circuit breaker failure protection (50BF), unbalanced-load protection (46) undercurrent supervision (37) lock out (86) parameter set switchover supervision functions circuit-breaker control flexible protection functions (characteristic key values f(*) without automatic reclosing without fault locator |
In stock
|
| 7SJ8011-5EB90-3FA0 L0R |
7SJ |
OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) IEC 61850, 100MBIT ETHERNET, ELECTR., DOUBLE, RJ45 CONNECTOR NO SYSTEM PORT A METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP GROUND FAULT PROTECTION IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR |
In stock
|
| 7SJ8022-5EB96-1FA1 L0A |
7SJ |
OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) PROFIBUS DP SLAVE, ELECTR.RS485 INTERFACE, PORT A (ON BOTTOM OF DEVICE) WITH ETHERNET INTERFACE (DIGSI, NOT IEC61850) RJ45 CONNECTOR METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>,I>>,I>>>,IP, TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>, IE>>,IE>>>, IEP GROUND FAULT PROTECTION IEE>.IEE>>,IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT WITH AUTOMATIC RECLOSING |
In stock
|
| 7SJ8031-5BB00-1FB0 |
7SJ |
OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V SURFACE-MOUNTING CASE SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT NO SYSTEM PORT NO SYSTEM PORT A METERING: FAULT RECORDING FUNKTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>,I>>>,IP TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>,IE>>,IE>>>,IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITONAL FUNCTIONS: DIRECTIONAL GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR |
In stock
|
| 7SJ8041-1EC96-3FC2 L0G |
7SJ |
OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A rated auxiliary voltage: DC 24, 48 V flush-mounting housing, screw terminals region US,ANSI,language US Engl. (language can be changed) front membrane US system interface port B (device bottom side, rear) DNP 3.0, electrical RS485 interface, Port A (device bottom side, front) with Ethernet interface (DIGSI interface, not IEC61850) RJ45 plug measurement: fault recording, mean-value generation, min./max. values functionality: overcurrent protection overcurrent protection PH(50/51 I>, I>>,I>>>,IP sensitive ground-fault protection overcurrent protection ground (50N/51N): IE>, IE>>, IEP ground fault/ground fault protection IEE>, IEE>>, IEEP overload protection (49) trip-circuit supervision (74TC) circuit breaker failure protection (50BF) unbalanced-load protection (46) undercurrent supervision (37) lock out (86) supplementary functions: determination of earth-fault direction directional element phase voltage protection, frequenc(*) with fault locator |